Page 3-46 G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air
Revision F 190-00682-01
3.9.7 TAWS B Enable
Follow this procedure to re-activate the TAWS Class B option. A TAWS Enable Card, as specified on
General Arrangement Drawing, listed in Table 1-2, will be required for this procedure. Section 3.9.8
installs the Terrain/Obstacle database card.
NOTE
The G1000 has various features that require the use of unlock/enable cards to activate the feature.
Throughout this document these cards are generically referred to as ‘enable cards’. In some cases, the
actual label on the physical card may say ‘unlock’. If uncertain, the technician should verify the card part
number prior to use.
NOTE
When the TAWS option is enabled for the first time (normally with the initial STC installation), the
G1000 writes its unique system ID to the physical card and locks the files to this unique ID. This
prevents the enable card from ever being used to activate TAWS in another G1000 system. This enable
card is tied to the specific aircraft in which it was used for the first time. For situations where TAWS
must be re-activated, this card must be used.
1. If not applied, apply power to the G1000 system.
2. Remove power from PFD 1, PFD 2 and MFD by opening the PFD 1 PRI/SEC, PFD 2 and MFD
circuit breakers.
3. Insert the TAWS Class B Enable card in the upper slot of PFD 1.
4. While holding the ENT key on the PFD 1, PFD 2 and MFD (for MFD press and hold the farthest
right pushbutton), restore power to the displays.
5.
When the words appear in the upper left corner of the displays,
release the ENT key
.
6. On PFD 1, go to the System Upload page using the small PFD 1 FMS knob.
7. Activate the cursor. Use the small PFD 1 FMS knob to select CONFIGURATION FILES in
the AIRFRAME field and press the PFD 1 ENT key.
8. Highlight the FILE field. Use the PFD 1 small FMS knob to select the ‘Enable TAWS’ option
and press the PFD 1 ENT key. Once the option is selected, the configuration files in the
PRODUCT field will be displayed. All files should be checked. If not, press the CHK ALL
softkey.
9. Press the LOAD softkey.
10. Monitor the status of the upload. When the upload is finished, press the PFD 1 ENT key to
acknowledge the upload complete confirmation.
11. View the SUMMARY field and ensure that the item is ‘COMPLETE’.
12. De-activate the cursor.
13. Power down the system and remove the TAWS Enable card from PFD 1.
Page view 75