Page view 38
G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air Page 3-9
190-00682-01 Revision F
3.7.1 SET>ACTV Configuration
Throughout the configuration mode pages, there are SET and ACTIVE columns for input/output settings
and other parameters.
SET:
Refers to a setting or group of settings that reside in PFD Internal Memory and/or the
Master Configuration Module.
ACTIVE:
Refers to an ‘active’ setting or parameter currently being used by the LRU. LRUs store
the ‘active’ settings within internal memory.
Data can be manually copied from one column to the other (and consequently from PFD memory to the
LRU memory and vice-versa) by using the following two softkeys, when available:
SET>ACTV (read ‘Set to Active’) softkey: Allows the installer to send the information in the SET
column (data stored in the master config module) to the ACTV column (data used by LRU).
ACTV>SET (read ‘Active to Set’) softkey: Causes the LRUs current settings to be copied to the
master configuration module as SET items.
CAUTION:
The ACTV>SET softkey must be used with caution! If an improperly configured unit is
installed, this softkey causes the wrong configuration to replace the correct aircraft
configuration.
SET>ACTV and ACTV>SET Softkeys
SET Column ACTIVE Column
Figure 3-11. SET and ACTV Softkeys and Columns