Page 3-10 G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air
Revision F 190-00682-01
When troubleshooting the system, technicians can look for inequalities between SET and ACTIVE
columns. Certain problems can be resolved simply by pressing the SET>ACTV softkey, which reloads
settings to the specific LRU from the PFD. (Note that this can also be accomplished by reloading the
configuration files for the LRU, using the software loader card. Section 7 describes this process for each
LRU).
A blank active column, as shown in Figure 3-12, represents loss of communication between the display
and the particular unit. See Section 5 for more details on troubleshooting.
Figure 3-12. Loss of Communication
3.7.2 Configuration Prompts
When configuration settings are changed, the technician receives on-screen prompts and/or confirmations
such as those shown in Figure 3-13. Section 7 shows other prompts encountered during the configuration
process.
Figure 3-13. Configuration Status