190-00590-00 Rev. C
Garmin G1000 Pilot’s Guide for the Quest Kodiak 100
A-10
APPENDIX A
Database Message Advisories (Cont.)
Alerts Window Message Comments
DB MISMATCH
– Basemap database
version mismatch. Xtalk is off.
The PFD and MFD have different basemap database versions installed. Crossfill is
off. Install correct basemap database version in both displays.
DB MISMATCH
Terrain database
version mismatch. Xtalk is off.
The PFD and MFD have different terrain database versions installed. Crossfill is off.
Install correct terrain database version in both displays.
DB MISMATCH
Terrain database
type mismatch. Xtalk is off.
The PFD and MFD have different terrain database types installed. Crossfill is off.
Install correct terrain database type in both displays.
DB MISMATCH
– Obstacle database
version mismatch. Xtalk is off
The PFD and MFD have different obstacle database versions installed. Crossfill is off.
Install correct obstacle database version in both displays.
DB MISMATCH
Airport Terrain
database mismatch. Xtalk is off
The PFD and MFD have different airport terrrain databases installed. Crossfill is off.
Install correct airport terrain database in both displays.
GMA 1347 Message Advisories
Alerts Window Message Comments
GMA1 FAIL – GMA1 is inoperative. Number 1 audio panel self-test has detected a failure. The audio panel is unavail
-
able. The G1000 system should be serviced.
GMA2 FAIL – GMA2 is inoperative. Number 2 audio panel self-test has detected a failure. The audio panel is unavail
-
able. The G1000 system should be serviced.
GMA1 CONFIG – GMA1 configuration
error. Config service req’d.
Number 1 audio panel configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
GMA2 CONFIG – GMA2 configuration
error. Config service req’d.
Number 2 audio panel configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
MANIFEST – GMA1 software
mismatch. Communication halted.
Number 1 audio panel has incorrect software installed. The G1000 system should be
serviced.
MANIFEST – GMA2 software
mismatch. Communication halted.
Number 2 audio panel has incorrect software installed. The G1000 system should be
serviced.
GMA1 SERVICE
– GMA1 needs
service. Return unit for repair.
Number 1 audio panel self-test has detected a problem in the unit. Certain audio
functions may still be available, and the audio panel may still be usable. The G1000
system should be serviced when possible.
GMA2 SERVICE
– GMA2 needs
service. Return unit for repair.
Number 2 audio panel self-test has detected a problem in the unit. Certain audio
functions may still be available, and the audio panel may still be usable. The G1000
system should be serviced when possible.
BACKUP PATHAudio panel 1 using
backup data path.
The #1 audio panel is using a backup communication path. The G1000 system
should be serviced when possible.