Garmin G950 Cockpit Reference Guide for the Tecnam P2006T
190-01147-00 Rev. A
48
Annunciations & Alerts
Flight
InstrumentsEIS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
GMA 1347 MESSAGE ADVISORIES
Message Comments
GMA1 FAIL
– GMA1 is inoperative.
The audio panel self-test has detected a failure.
The audio panel is unavailable. The G950 system
should be serviced.
GMA1 CONFIG
– GMA1 config
error. Config service req’d.
The audio panel configuration settings do not
match backup configuration memory. The G950
system should be serviced.
MANIFEST – GMA1 software
mismatch, communication halted.
The audio panel has incorrect software installed. The
G950
system should be serviced.
GMA1 SERVICE – GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem.
Certain audio functions may still be available, and the
audio panel may still be usable. The
G950
system
should be serviced when possible.
GIA 63W MESSAGE ADVISORIES
Message Comments
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do
not match backup configuration memory. The
G950 system should be serviced.
GIA2 CONFIG
– GIA2 config error.
Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio
configuration. The G950 system should be
serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
GIA1 COOLING
– GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING
– GIA2 temperature
too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high.
If problem persists, the G950 system should be
serviced.
GIA2 COOLING
– GIA2 over
temperature.